| dd barometer of belgium | ||
| how an eco-celli barometer works | ||
| page 3 of 3 |
|
|
|
Calibration of the Eco-celli Barometer
The Eco-celli barometer is calibrated to sea level (0 feet). When you install the barometer in an area that has a different height (more than 100 feet) above or below sea level, you will need to calibrate your barometer. A calibration kit comprised of a syringe, needle stub, and capillary tube was included with your barometer. There are two methods of calibration. Method one: the first thing you will need is the current local air pressure. Contact a local airport, television station, National Weather Service office, or visit a weather web site such as weather.com. Once you have the correct local air pressure, remove fluid from the red tube using the calibration set until the fluid level matches the correct air pressure. Have paper towels available to catch any spills as the colored oil will stain anything it comes in contact. The second calibration method is to calculate the air pressure difference from sea level. To find your height above sea level, contact your local city/town hall. Each 25 feet above sea level is equal to 0.03 inches on the scale. Remove the calculated amount of fluid until the correct fluid level is reached. Please save the removed fluid in the syringe so it may be added if the barometer is moved to a different location. |
||
|
Important Notes:
CAUTION WITH HIGH TEMPERATURES. The barometer is very heat sensitive. Do not place this barometer on places that will be overheated by the sun. The barometer will not function properly and the thermometer will be damaged if the temperature is above 120 degrees F.
SPILLING OF THE COLORED FLUID. If the red barometer fluid id spilled, you must act very quickly. The fluid is not hazardous, but is a very strong colorant. Use lots of water to rinse the stain. Then use warm water and soap to clean the stain to prevent permanent coloring.
TRANSPORTATION. If the barometer is to be transported, you should close the end of the barometer tube with the rubber hose and rubber stopper.
MAINTENANCE. Use a dry lint free cloth. Use of abrasive cleaning products is prohibited. Woodwork and metal parts can be maintained with the help of a bee-wax containing spray and lint free cloth. DO NOT spray directly onto the instrument. Spray a bit of product onto a cloth and gently rub the woodwork and metal parts.
| ||
|
|
|
|
| Toll-Free Customer Service: 1-800-210-0492 | Mon-Fri: 9:00 am to 6:00 pm EST | Sat: 8:00 am to 12:00 noon EST |
| Contact Us: service@bellclocks.com | Visit our Company Website at: WindwardInstruments.Com |
|
|
|
About Your Order:
• Track Your Order • Questions About Your Order • Satisfaction Guarantee |
Shipping & Returns Help
• Shipping Costs & Times • Our Return Policy |
Additional Information: •Help |
||||||
|
|